move_detect/edge/daemon.py
유창욱 c385be017c fix(edge): resilient multi-camera startup — skip a camera that fails to construct
build_runtimes() builds each camera's source+runtime in a try/except: a camera that
raises at construction (e.g. an unseated/absent CSI camera whose Picamera2(...) throws)
is logged and skipped so the working cameras still run, instead of an unguarded
exception crash-looping the whole daemon (Restart=always). Raises only if no camera
comes up. Closes the eager-construction gap the review flagged.
2026-07-13 23:47:20 +09:00

135 lines
6 KiB
Python

import os
def run_loop(runtime, client, queue, *, clock, sleep, iterations=None,
sync_every=150, heartbeat_every=900, flush_every=300,
frame_interval=0.0, zones_for=None):
# `runtime` may be a single PipelineRuntime or a list of them (multi-camera). All
# cameras share this loop, one shared clock read per tick, and the periodic
# sync/heartbeat/flush. A per-camera step exception is counted, never fatal.
runtimes = list(runtime) if isinstance(runtime, (list, tuple)) else [runtime]
if zones_for is None:
from edge.zones import zones_from_config
zones_for = lambda cfg, rt: zones_from_config(cfg)
counters = {"frames": 0, "syncs": 0, "beats": 0, "flushes": 0, "errors": 0}
i = 0
while iterations is None or i < iterations:
i += 1
now = clock() # one timestamp per tick, shared across cameras
for rt in runtimes:
try:
rt.step(now)
counters["frames"] += 1
except Exception:
counters["errors"] += 1
try:
if sync_every and i % sync_every == 0:
cfg = client.fetch_config()
if cfg is not None:
for rt in runtimes:
rt.apply_zones(zones_for(cfg, rt))
counters["syncs"] += 1
if heartbeat_every and i % heartbeat_every == 0:
if client.send_heartbeat({"fps": 0.0, "frames": counters["frames"]}):
counters["beats"] += 1
if flush_every and i % flush_every == 0:
queue.flush()
counters["flushes"] += 1
except Exception:
counters["errors"] += 1
if frame_interval:
sleep(frame_interval)
return counters
def parse_cameras(env, default_camera_id):
"""CAMERAS='backend:device:camera_id,...' -> [(backend, device, camera_id), ...].
When CAMERAS is unset, fall back to a single camera from
CAMERA_BACKEND + {UVC,CSI}_DEVICE (using default_camera_id)."""
raw = (env.get("CAMERAS") or "").strip()
if raw:
cams = []
for spec in raw.split(","):
spec = spec.strip()
if not spec:
continue
parts = [p.strip() for p in spec.split(":")]
if len(parts) != 3:
raise ValueError(f"bad CAMERAS entry {spec!r} (want backend:device:camera_id)")
cams.append((parts[0].lower(), parts[1], parts[2]))
if not cams:
raise ValueError("CAMERAS is set but has no valid entries") # never monitor zero cameras
return cams
backend = (env.get("CAMERA_BACKEND") or "uvc").lower()
device = env.get("CSI_DEVICE" if backend == "csi" else "UVC_DEVICE") or "0"
return [(backend, device, default_camera_id)]
def build_runtimes(cameras, make_source, make_runtime, log=None):
"""Build one (source -> runtime) per camera. A camera that fails to CONSTRUCT
(e.g. an unseated/absent CSI camera whose Picamera2(...) raises) is logged and
SKIPPED so it never crash-loops the whole daemon and the other cameras still run.
Raises if no camera comes up (never run monitoring nothing)."""
if log is None:
import sys
log = lambda m: print(m, file=sys.stderr)
runtimes = []
for backend, device, cam in cameras:
try:
runtimes.append(make_runtime(cam, make_source(backend, device)))
except Exception as e:
log(f"camera {cam} ({backend}:{device}) failed to start, skipping: {e}")
if not runtimes:
raise RuntimeError("no cameras could be started")
return runtimes
def main() -> None: # pragma: no cover (integration entrypoint, exercised on device)
import time
from dataclasses import replace
from edge.config import load_config
from edge.cloudclient import CloudClient
from edge.alert import PostClient
from edge.queue import OfflineQueue
from edge.runtime import PipelineRuntime
from edge.zones import zones_from_config
def build_source(backend, device):
if backend == "csi":
from edge.adapters.picamera_source import PiCameraSource
return PiCameraSource(int(device))
from edge.adapters.uvc_source import UvcSource
return UvcSource(int(device))
def build_pose():
# POSE_BACKEND: "hailo" (Pi5 + Hailo-8, needs HAILO_HEF) or CPU "movenet"
# (needs MOVENET_ONNX). One shared adapter serves every camera (the Hailo
# device / onnxruntime session is reused per frame, round-robin across cams).
if os.environ.get("POSE_BACKEND", "movenet").lower() == "hailo":
from edge.adapters.hailo_pose import HailoPoseAdapter
return HailoPoseAdapter(os.environ["HAILO_HEF"])
from edge.adapters.movenet_pose import MoveNetPoseAdapter
return MoveNetPoseAdapter(os.environ["MOVENET_ONNX"])
cfg = load_config(dict(os.environ))
nonce = lambda: os.urandom(8).hex()
now = time.time
base = cfg.cafe24_url.rstrip("/")
client = CloudClient(base, cfg.device_id, cfg.secret, nonce, now)
post = PostClient(base + "/api/events", cfg.device_id, cfg.secret, nonce, now)
queue = OfflineQueue(os.environ.get("QUEUE_DB", "queue.db"), post)
pose = build_pose() # shared across cameras
def make_runtime(cam, source):
# Per-camera config so events are stamped with that camera's id.
cam_cfg = replace(cfg, camera_id=cam, engine=replace(cfg.engine, camera_id=cam))
return PipelineRuntime(cam_cfg, source, pose, queue)
# A missing/unseated camera is skipped (logged), not fatal — the others still run.
runtimes = build_runtimes(parse_cameras(dict(os.environ), cfg.camera_id),
build_source, make_runtime)
run_loop(runtimes, client, queue, clock=now, sleep=time.sleep, iterations=None,
frame_interval=1.0 / float(os.environ.get("TARGET_FPS", "12")),
zones_for=lambda c, rt: zones_from_config(c, rt.camera_id))